FireShield
Family
Fire Alarm Control Systems
 Edwards is a registered trademark of UTC Fire & Security
 

The Edwards FireShield fire alarm family consists of 3,5 and 10 zone conventional fire alarm control panels, integrated DACT/Dialer, serial annunciator modules and serial remote relay modules. All of these components are microprocessor-controlled. The FireShield family is ideal for both new and retrofit installations alike.

Edwards FireShiled incorporates features designed to simplify installation, operation and maintenance. These include front panel programming, one person walk testing, and selectable IDC and NAC styles. In addition, each IDC can be programmed for one of eight types including waterflow and supervisory.

Options for the FireShield panels include serial bus relay modules programmable for common or zone activation, serial bus remote annunciators, city tie and reverse polarity modules, and optional trim rings for semi-flush mounting. An optional fully integrated DACT/Dialer provides 32 character LCD display, event history log, supports both contact ID and 4/2 formats, and upload/download of Panel/DACT configuration, status and event history.

FireShiled panels are powerful enough to meet the demands of today's installations while leaving plenty of room to grow in the future.

 
Features
Available in three, five and ten Style B initiating device circuit (IDC) models
2 or 4 Style Y notification appliance circuits
IDC or NAC convertible to Class A circuits (ten and five zone panels only) without additional modules
Supports ED2M, SC Series and 2400 Series detectors. A complete list of cross-listed smoke detectors is available on request.
Genesis option provides precision strobe synchronization and audible silence over two wires without additional modules.
IDC programmable for alarm verified or alarm non-verified, waterflow or supervisory condition.
Programmable NACs individually selectable for Genesis, continuous or temporal output.
One man walk test (audible or silent)
Optional serial bus relay modules are programmable for common or zone activation.
Expandable transformer adds 2.5 amps to ten zone panel.
On-board relays for alarm, supervisory and trouble conditions.
Optional full integrated DACT/Dialer:
Event history log
Upload/download of configuration, status and event history
Supports Contact ID and 4/2 formats
Agency Approvals
UL, ULC & CSFM Listed, MEA Approved
Click for Brochure
270-DOC EDWARDS Fire Alarm Station - Single Action, Double Pole, One Open Circuit, One Closed Circuit /  Brochure
270-DPO EDWARDS Fire Alarm Station - Single Action, Double Pole, Open Circuit /  Brochure
270-SPO EDWARDS Fire Alarm Station - Single Action, Single Pole, Open Circuit /  Brochure
270A-DPO EDWARDS Fire Alarm Station - Single Action, Doublle Pole, Open Circuit, Wire Leads /  Brochure
270A-SPO EDWARDS Fire Alarm Station - Single Action, Single Pole, Open Circuit, Wire Leads /  Brochure
270P-SPO EDWARDS Fire Alarm Station - Single Action, Single Pole, Open Circuit, Pre-Signal Switch /  Brochure
278B-1110 EDWARDS Fire Alarm Station - Double Action, Normally Open, Single Pole, Tool Operated Reset /  Brochure
278B-1120 EDWARDS Fire Alarm Station - Double Action, Normally Open, Single Pole Contact, Key Reset /  Brochure
278B-1130 EDWARDS Fire Alarm Station - Double Action, Normally Open/Closed, Double PoleContact, Key Reset /  Brochure
| Brochure | Doc | Spec Sheet | User Guide | Manual | Wiring |