Lee Dan Enterlok 2-station door answering intercom system


ENTERLOK™ WIRING INSTRUCTIONS
Innovations in Communications™ Since 1955

SM-201 MASTER STATION
 
Popular EnterlokTM Components:
Lee Dan IR-501B indoor intercom remote Lee Dan OR-103 aluminum outdoor remote Lee Dan OR-203 aluminum outdoor remote Lee Dan OR-201SS stainless steel outdoor remote Lee Dan OR-203SS stainless steel outdoor remote Lee Dan RH-15 patio horn SM-201 Enterlok intercom master station
IR-501B

ABS Plastic
Remote
Plastic button
OR-103

Aluminum Remote
Plastic button+grill
OR-203
All Alum. Remote
Metal Button
OR-201SS

Stainless Steel
Remote
No call button
OR-203SS

Stainless Steel
Remote
Metal button
RH-15

12 Watt Round White
Plastic Patio Horn
SM-201

ENTERLOKTM
Master Station

APPLICATION
The SM-201 ENTERLOKTM intercom is a multi-purpose, two-station intercom suitable for homes, offices, or wherever communication to a single location plus convenient electrical door opening is needed. The solid state design, combined with low voltage operation, permits easy and simple installation.

INSTALLATION PROCEDURE
1) Read installation instructions before proceeding. 2) Install housings and wiring.
3) Connect wiring and install equipment. 4) Apply power and check operation.

EQUIPMENT LOCATION & INSTALLATION HOUSING
Lee Dan IH-102 installationInside Remote
Locate remote station where needed at convenient speaking height. Do not install back to back or on a common wall with the master station.

Install IH-102 housing for IR-501B, IR-510B remotes. Reverse housing for use on finished walls as shown in Fig.1 below. Leave about 2" (5cm) of wall space on all sides.

Use IH-400A cabinet for desk mounting. Use IH-700 surface box for surface mounting.

Outside Remote
For outside stations OR-103, OR-510, OR-203, OR-203SS install IH-101(flush) or OH-700(surface) box.

For OR-600 series outside stations, use single gang ring or box. Run wire/cable to remote speaker location.

Master Station
Locate master station where needed and at a convenient speaking height. Do not locate master near any source of direct heat, or too close to transformers, light dimmers or other electrical devices or wiring.

Do not install master close to or on a common wall with remote station. Install single gang electrical box or surface mount using Lee Dan IH-400A.
 

Transformer - IMPORTANT!
Connecting this equipment to any power source other than a standard 16-volt AC, 10 V.A. chime transformer, or the LEE DAN transformers specified, voids all guarantees.

Plug-In:
A PS-20A plug-in type transformer may be used and must be provided with an electrical outlet at some convenient location within 50 feet of the master.

Pigtail
A PS-3A or PS-30A type transformer may be used and may be installed on the fuse panel or any other accessible source of 117 volts A.C. within 50 feet of the master station. (Observe all local electrical codes.)

WIRING
 
Lee Dan SM-201 Enterlok wiring diagram FIGURE 4 NOTES:
1) Add wire jumper to IR-501B, OR-103, OR-203 or OR-203SS remote stations as shown.

2) Add 15-MFD (15-mfd. non-polarized) capacitor to IR-501B, OR-101, OR-103, OR-201, OR-201SS, OR-203, OR-203SS, OR-601, OR-603 or RH-15 remote stations as shown.

One 15-MFD capacitor is packaged with each SM-201 master. 

3) Locate remote station type on Fig. 4, and wire as shown using 2 conductor #22 twisted pair wiring.

4) Use #18 wire for door release and transformer wiring.

5) You can use any of the remotes shown on Fig. 4, but not more than two per system! Call Lee Dan for details.

Run 2 conductor twisted #22 cable from the master station directly to the remote station.NOTE: It is recommended that shielded cable be used from the master to the remote station when the cable must be run near any AC wires!

Run 2 conductor #18 cable from the SM-201 master to the transformer location.

Run 2 conductor #18 cable from the SM-201 master to the door opener location. Leave sufficient cable at each end to make connections (about 10" ).

Call your local LEE DAN® distributor, or our customer service department toll-free for more information.

CAUTION! Do not run door opener or transformer wires together with intercom wires!

Make connections as shown on the Typical Wiring Diagram (Figure 4) or the Alternate Diagram for 24-volt door opener (Figure 3).

NOTE: If the door opener operation from the SM-201 master is not needed, the DOOR button may be used for other signal purposes. Simply run the door cable to the optional signal device (bell, buzzer, etc.) which must be able to operate on 16 volts A.C., 10 V.A. or less.

Lee Dan 24 volt Enterlok door release diagramSM-201 OPERATION &
CHECK-OUT INSTRUCTIONS

At Remote Speaker
Push button to call master, release to allow communication by master.

At Master Speaker
1) Push TALK button to speak; release to LISTEN.
2) Push DOOR button to open door.
3) Push OFF button to silence speaker, if desired. Station will remain in monitor mode if OFF button is not pushed.
4) Press TALK button to re-activate speaker.
5) Adjust VOLUME with small screwdriver if needed, through hole provided on lower front of panel.

NOTE: If the volume is too high, distortion or howling may result.

SM-201 BrochureIntercomsEnterview Video Intercom

 